| Input
(Control) Specifications |
Min. |
Max. |
Units |
| Control Voltage Range |
3
75
|
32
240
|
VDC
AC
|
| Input Current (-40*C<Ta<80*C) |
|
20 |
mA |
| Turn-On Voltage (40*C<Ta<80*C) |
75 |
260 |
VDC
AC
|
| Turn-Off Voltage (-30*C<Ta<80*C) |
|
1
4
|
VDC
AC
|
| Isolation (Input to Output,
Input to Case Output Case) |
10 |
|
OHMS |
| Capacitance (Input to Output) |
|
10 |
Pf |
| Dielectric Strength (Input
& Output to Case) |
2500 |
|
Vac (RMS) |
| Reverse Voltage Protection |
32 |
|
VDC |
| Output (Load) Specifications |
Min. |
Max. |
Units |
| Output Current Rating with
Heal Sink |
0.05 |
10 25
15 40
|
AMPS
(RMS)
|
| Load Voltage Rating |
25 |
480 |
VAC(RMS) |
| Frequency Range |
47 |
70 |
Hz |
| Surge Current Rating (20ms)
at 40 Amp Type |
425 |
AMP |
|
| Over Voltage Rating (Transient
Peak) |
1200 |
|
V Peak |
| Contact Voltage Drop at Rated
Current |
|
1.5 |
VAC (RMS) |
| Turn-On Time(50HZ) |
|
10 |
mS |
| Off state leakage Max. at
240 VAC |
|
10 |
mA (RMS) |
| SCR Power device Dissipation
Factor (D) |
|
1.3 |
WATTS/AMS |
| SCR Junction temperature (T)
Max. |
|
100 |
*C |