Satronix

  Relays : normal Open TYPE 1..., normal Open TYPE 2..., 3 - Phase TYPE...
   
  Solid State Relays
 
3 - Phase TYPE Optically Isolated
  Switches 10 to 40A Loads
 

Features:

  • Available are economical photocoupler isolation which can be connected directly to IC logic circuits such as DTL, TTL, CMOS etc.
  • Zero voltage turn-on; zero current turn-off
  • Dielectric strength (Input & Output to Case) 2500 VAC
  • No noise feedback from output to input circuits
  • No noise due to load current switching at near zero point.
  • Faster switching response.
  • Requires minimum actuation power.
  Part Numbering:-
 
Input Control Output Voltage Rating (VAC) Output (Load) Current Rating & Part Numbers
Voltage Range Continuous (RMS) Transient (PEAK) 10Amp 15Amp 25Amp 40AMp
3.32 VDC 440 1200 SD- 440-10 SD- 440-15 SD- 440-25 SD- 440-40
75240 VAC 440 1200 SDA- 440-10 SDA- 440-15 SDA-440-25 SDA- 440-40
  ELECTRIC SPECIFICAITONS (25 c UNLESS OTHERWISE NOTED)
 
Input (Control) Specifications Min. Max. Units
Control Voltage Range

3

75

32

240

VDC

AC

Input Current (-40*C<Ta<80*C)   20 mA
Turn-On Voltage (40*C<Ta<80*C) 75 260

VDC

AC

Turn-Off Voltage (-30*C<Ta<80*C)  

1

4

VDC

AC

Isolation (Input to Output, Input to Case Output Case) 10   OHMS
Capacitance (Input to Output)   10 Pf
Dielectric Strength (Input & Output to Case) 2500   Vac (RMS)
Reverse Voltage Protection 32   VDC
Output (Load) Specifications Min. Max. Units
Output Current Rating with Heal Sink 0.05

10 25

15 40

AMPS

(RMS)

Load Voltage Rating 25 480 VAC(RMS)
Frequency Range 47 70 Hz
Surge Current Rating (20ms) at 40 Amp Type 425 AMP  
Over Voltage Rating (Transient Peak) 1200   V Peak
Contact Voltage Drop at Rated Current   1.5 VAC (RMS)
Turn-On Time(50HZ)   10 mS
Off state leakage Max. at 240 VAC   10 mA (RMS)
SCR Power device Dissipation Factor (D)   1.3 WATTS/AMS
SCR Junction temperature (T) Max.   100 *C
 

Note:-

  1. Rating is based on a single mounted unit in free air flow. Closely packed units will result in restricted air flow and careful consideration of the ambient temperature will be necessary.
  2. For additional transient over - voltage protection, use metal oxide varistors; and for current protection, use semiconductor fuses.
  3. For load current > 3 Amps external heat sink has to be used. (*Refer to Thermal Derating Curve).
   
 
  Sunflower Export Import Pvt. Ltd. is a MAHESH (INDIA) Group Company.